description2
SSY-EG Pure Water Treatment System
Product Introduction
Technical Features
Model |
Capacity |
Power |
Input Power |
Overall Size |
SSY-EG-200L |
200L/H |
2.2KW |
AC220V/50HZ |
1100*730*1600mm |
SSY-EG-250L |
250L/H |
2.2KW |
AC220V/50HZ |
1100*730*1600mm |
SSY-EG-300L |
300L/H |
2.2KW |
AC220V/50HZ |
1100*730*1600mm |
SSY-EG-500L |
500L/H |
2.5KW |
AC220V/50HZ |
1100*730*1600mm |
Technical Parameter
Model: |
SSY-EG-200/250/300/500L/H |
Capacity: |
200/250/300/500L/H |
Environment Temperature: |
5-45℃ |
Raw Water Pressure: |
0.2-0.4Mpa |
Productive Water Quality Index: |
one stage conductivity value:<15μs/cm;two-stage conductivity value:≤5μs/cm@25℃ Bacterial Removal Rate≥99.6% Particle (>0.2μm) <1 piece/ml Ion Retention Rate:97%-99% Organic matter retention rate>99% Meet WS 310.1.2.3-2016 Technical Specification for Cleaning and Disinfection of Hospital Disinfection Supply Center (Supply Room) |
Application: |
Operating room instrument cleaning |
SSY-EG Process Flow Diagram
Raw water → Raw water tank → Raw water pump → Quartz sand tank → Activated carbon tank → Resin softening tank → Salt tank → Security filter → High pressure pump → Reverse osmosis membrane →Pure water tank → Delivery pump → Water point